Home > News > Content
Best One Inch Standard Port Male Globe Auto Ball Valve (HTW-EG)
- Nov 03, 2017 -

Basic Info

  • Model NO.: HTW-EG

  • Connection Form: Thread

  • AC Actuator Power Supply: 220VAC/110VAC/24VAC/12VAC Optional

  • Actuator Output Type: Spdt/Spst Optional

  • Valve Size: 1/2′′(Dn15)-3/4′′(Dn20)-1′′(Dn25)

  • Pressure (MPa): 1.6MPa

  • HS Code: 84819010

  • Material: Brass

  • Application: Industrial Usage, Water Industrial Usage, Household Usage

  • DC Actuator Power Supply Optional: DC6V,DC9V,DC12V Optional

  • Port: 2 Port(Way)/3 Port(Way)

  • Connection Type: Male Connection

  • Liquid Temperature: 1~95°c

Product Description

General

Best One Inch Standard Port Male Globe Auto Ball Valve(HTW-EG) are used to control the on/off of heat/cool water air-conditioning system pipe to control the room temperature.  The valve is driven by synchronous motor.  The motor connects with room thermostats by the terminal of common, open and close.  By sampling and dealing with the site data, the thermostats send control signal to open/close the motor of ball valve.  Then the heat/cool water enters into fan coil unit to supply the heat or cool air.  When the room temperature reaches the set-point, thermostat will send a signal to cut off the ball valve and make it on the best status. Then the room temperature will keep in the comfortable range.
Valve thread size: G1/2,G3/4,G1,G1.1/4
Thread connection. Valve body could be installed first.  Simple wiring. The actuator could be installed near to the wall.

Technical Parameters

• Driving voltage:220VAC (12V, 24V, 110VAC optional)
• Power consumption:5VA (only during course of open and close) 
• Pressure-bearing of valve body:1.6MPa
• Allowance pressure:≤0.6MPa 
• Applicable medium:cool water, hot water and low pressure steam (≤0.4MPa) 
• Open and close time:two-way 30s, three-way 57s. 
• Temperature of applicable medium:1ºC-130ºC
• Applicable environment temperature:0ºC-65ºC
• Connection manner:ZG internal pipe thread (could be customized)

Wiring Diagram

Model Comparison Table

ModelValveValve
 Size
Flux
Value(KV)
ZizeClosing
Pressure
(MPa)
Work
 Medium
Media Temp.Ambient 
Temp.
Pressure
(MPa)
Power Supply
HTW-EG-2152-wayDN153.6(4.6)G1/21.0Chilling water/
hot water





2-90ºC





-5-60ºC





2.5
 
 
AC24V
AC110V
AC220V
50/60HZ
HTW-EG-3153-wayDN153.6(4.6)G1/21.0
HTW-EG-2202-wayDN206.6(7.4)G3/40.8
HTW-EG-3203-wayDN206.6(7.4)G3/40.8
HTW-EG-2252-wayDN2512.2(13.5)G10.7
HTW-EG-3253-wayDN2512.2(13.5)G10.7
HTW-EG-2322-wayDN3214.6(16.3)G1.1/40.6